Design selective Cu2+ chemo-sensor based on Bis-Azo dye for determination of Cu2+ in water samples

نویسندگان

1 Department of Chemistry, Payame Noor University, Tehran, Iran

2 Department of Chemistry, Payame Noor University, Tehran, Iran

3 Department of Chemistry, Payame Noor University, Tehran, Iran

doi
10.22034/crl.2024.435316.1279
چکیده

In this work, a new bis-azo dye (BAD) was synthesized and characterized by Fourier-transform infrared (FT-IR) and nuclear magnetic resonance (NMR) spectroscopy. This ligand was used for selective determination of Cu2+ at trace levels in the aqueous solution. In the presence of Cu2+, the color change of ligand from red to orange pale (under visible light) was seen. Under optimized conditions, the limit of detection and quantification were found to be 0.13 and 0.44 µM, respectively. Dynamic range was found in the concentration range of 1.6 –17.5 µM with a correlation coefficient of 0.9964. This sensor was reversible and the response time was estimated nearly 6 minutes. The stoichiometric ratio between the chemosensor bis-azo dyeCu2+ [BAD-Cu2+] complex was determined to be 1:1 according Job’s plot. The results showed that this sensor was successful in determining Cu2 + in tap and mineral water samples.