An investigation into the accelerometer mounting effects on signal transmissibility in modal measurements
نویسندگان
1 Malek Ashtar University of Technology, Space Research Institute, Modal Testing laboratory, Lavizan, Tehran 14665/143, Iran
2 Malek Ashtar University of Technology, Space Research Institute, Modal Testing laboratory, Lavizan, Tehran 14665/143, Iran
3 Iran University of Science and Technology, School of Mechanical Engineering, Narmak, Tehran 16844, Iran
doi
10.24200/sci.2017.4244چکیده
The purpose of this study is to define a simple model and discuss the main effects due to the use of the sensors with imperfect mounting in experimental measurements. This paper presents a theoretical and experimental investigation for the effects of different mounting methods of accelerometers on signal transmissibility in modal testing. In the theoretical part, a two degree-of-freedom (2-DOF) model is used, where the first DOF accounts for the accelerometer seismic mass and Piezo-crystal and the second DOF represents the mounting interface dynamics. An experimental modal analysis is conducted on a simple steel free-free beam using impact hammer excitation. The time domain signals and frequency response functions (FRFs) are measured in the case of magnetic, wax and stud mounting. It is found that the method of mounting has a significant effect on damping rates of measured responses. Although natural frequencies have no important changes, but the quality of measured FRFs is degraded considerably.