Comparison of different DNA extraction and preparation methods for forensic application of Blood Samples
نویسندگان
1 دانشگاه علوم پزشکی فسا
2 دانشگاه علوم پزشکی تهران
doi
10.30505/7.4.167چکیده
Abstract Introduction: Extraction of DNA from forensic samples is the first and one of the most crucial steps of any genetic forensic test. Hence, obtaining a suitable protocol of extraction DNA that is easy to extract, cost, time, and quality which is essential in the forensic genetic research. Aims : The present study was carried out to achieve a suitable, faster and low cost method of DNA extraction from different sample for further molecular study. Materials & Methods: After preparation of samples, three different DNA extraction methods, including chelex, non-enzymatic and modified rapid alkaline lysis were evaluated. In order to compare the above mentioned methods for evaluation ease of extraction, low cost and time , the quality and quantity of DNA obtained from each method considering OD, DNA concentration and PCR efficiency were investigated. Results: The findings of this study show that despite the availability and lower cost and time of manual methods, these methods can be substitute for kit method .