Modeling of Tactile Detection of an Artery in a Soft Tissue by Finite Element Analysis
نویسندگان
1 M. Moini is with Sina Trauma and Surgery Research Center, Tehran University of Medical Sciences, Tehran, Iran (email: moinim@hotmail.com)
2 A. Abouei Mehrizi is with the Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran (email: abouei.ali@gmail.com).
3 Corresponding Author, S. Najarian is with the Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran (email: najarian@aut.ac.ir).
doi
10.22060/eej.2009.285چکیده
Nowadays, one of the main problems encountered in minimally invasive surgery and telesurgery is the detection of arteries in tissue. In this study, for the first time, tactile detection of an artery in tissue and distinguishing it from the tumor has been modeled by finite element method. In this modeling, three 2D models of tissue have been created: tissue, tissue including a tumor, and tissue including an artery. After solving three models with similar boundary conditions and loadings, first, the 2D tactile mappings and stress graphs for upper nodes of models, which have the role of transferring tactile data, have been explored. Comparing these results, if stress values of nodes are equal and constant, tissue is without tumor or artery. In addition, it was concluded that if stress graph includes a peak, the tissue has a tumor or an artery and that the stress graph of tissue including artery is time-dependent in comparison with the tissue including the tumor.