Optimized Er: YAG Laser Irradiation Distance to Achieve the Strongest Bond Strength Between Orthodontic Brackets and Zirconia-Ceramics
نویسندگان
1
2
3
4 Laser Research Center of Dentistry (LRCD), Faculty of Dentistry of Tehran University of Medical Sciences
5
6
doi
23950چکیده
Introduction: In recent decades zirconium oxide has been introduced in the field of dentistry as a high-strength ceramic. Unlike its mechanical advantages, however, due to its inert chemical properties, it bonds poorly to other substrates, so improving bonding strength to an adhesive material is necessary.Methods: In this experimental study, 70 ceramic zirconia blocks were prepared and distributed randomly among 7 groups. Then the shear bond strengths were determined and the samples were examined by a scanning electron microscope (SEM). Statistical analysis was performed by one-way ANOVA and multiple Tukey comparisons.Results: One-way analysis of variance (ANOVA) showed that laser irradiation distance has a significant effect on orthodontics brackets bond strength to zirconia-ceramics. Based on the Tukey post hoc test, each group was compared with other groups and the contact mode and 2 mm distance groups showed significantly higher bond strength than other groups (P-value <0.05).Conclusion: Orthodontic bracket bond strength to zirconia-ceramics will be reduced by increasing Er: YAG laser irradiation distance from samples. The highest bond strength will be achieved when the laser irradiation distance is 2 mm or when the laser beam is in contact with samples.