Prostate Biopsy Using Transrectal Ultrasonography; The Optimal Number of Cores Regarding Cancer Detection Rate and Complications

نویسندگان
doi
10.5812/iranjradiol.13257
چکیده

Background: Transrectal ultrasound guided biopsy of the prostate is the most common modality used to diagnose prostate cancer. Objectives: The aim of this study was to evaluate the optimal number of cores at prostate biopsy, which have the most diagnostic value with least adverse effects. Results: Prostate cancer was diagnosed in 8 (13.3%), 21 (35%) and 24 (40%) patients in six, twelve and eighteen core biopsy groups, respectively. Urinary tract infection and prostatitis occurred in 17 (28.3%), 23 (38.3%) and 35 (58.3%) patients in six, twelve and eighteen core biopsy groups, respectively. Considering the detection rate of prostate cancer, there was a significant difference between 6 and 12 core biopsy groups (P = 0.006) and 12-core biopsies detected more cases of prostate cancer, but there was no significant difference between 12 and 18 core biopsy groups (P = 0.572). Considering the infection rate, there was no significant difference between 6 and 12 core biopsy groups (P = 0.254), but there was a significant difference between 12 and 18 core biopsy groups (P = 0.028) and infectious complications occurred more frequently in 18-core biopsy group. Conclusions: The best balance between detection rate of prostate cancer and infectious complications of biopsies achieved in twelve-core biopsy protocol. Twelve-core biopsy enhances the rate of prostate cancer detection with minimum adverse effects.

کلیدواژه‌ها