Quantitative Measurement of Oxygen Extraction Fraction (OEF) Using Respiratory Modulated Perfusion MRI
نویسندگان
doi
10.5812/iranjradiol.64253چکیده
Background: Measurement of oxygen consumption can give useful information of brain functionality in health and disease. To have a better understanding of normal physiology in all conditions (rest or functional tasks), development of accurate brain oxygen mapping is essential. This mapping could also be a great help in managing pathological conditions with disturbance in oxygen supply. One of the most important hemodynamic parameters of the brain is oxygen extraction fraction (OEF). By development of blood oxygen level dependent magnetic resonance imaging (BOLD MRI) in imaging, several methods have been proposed for measuring this parameter. The latest methods are mostly based on hypercapnic and hyperoxic stimulus. Objectives: Here, we presented a new method with hypercapnic and hyperoxic stimulus and using BOLD and dynamic susceptibility contrast (DSC) perfusion imaging instead of arterial spin labelling (ASL). Results: Comparable results were acquired for OEF with previous studies. The mean value of estimated OEF for gray matter (GM), white matter (WM) and whole brain is 0.46, 0.37, and 0.44, respectively which are within the expected range of normal condition. Conclusion: As the proposed method for OEF measurement uses a combination of hyperoxic and hypercapnic stimulus with BOLD and DSC-perfusion imaging, it could be considered the most available one in all MRI scanners and being a voxel wise method, it could give OEF value for any requested ROI.